datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Keithley pa703a-Model 4200MTRX-X0

Keithley pa703a-Model 4200MTRX-X0 free download

Various electronics service manuals

File information:
File name:pa703a-Model_4200MTRX-X0.pdf
[preview pa703a-Model 4200MTRX-X0]
Size:21 kB
Extension:pdf
Mfg:Keithley
Model:pa703a-Model 4200MTRX-X0 🔎
Original:pa703a-Model 4200MTRX-X0 🔎
Descr: Keithley SCS 4200 pa703a-Model_4200MTRX-X0.pdf
Group:Electronics > Other
Uploaded:02-02-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name pa703a-Model_4200MTRX-X0.pdf

Model 4200 MTRX-X Triax Cable Assembly Packing List Description The Model 4200-MTRX-X Triax Cable connects the installed Source-Measurement Unit (SMU) in the Model 4200-SCS (Semiconductor Characterization System) to the device under test (DUT). Model 4200-MTRX-X (Figure 1) consists of standard triax cable terminated with a miniature male triax connector on one end and a standard 3-slot male triax connector on the other end. The miniature triax connector mates to the FORCE connector on the 4210-SMU or 4200-SMU installed in the system. The standard triax connector connects to the test fixture or probe station holding the DUT. CAUTION The Model 4200-MTRX Triax Cable is intended for connection only to an SMU that does not have a PreAmp installed. NEVER make connection to any miniature triax connector on an SMU if a PreAmp is installed. Otherwise, damage to the SMU and/or the DUT, and/or corrupt data may occur. The 4200-MTRX-X is available in three lengths. The -X in the model number represents the cable length in meters, as listed in Table 1. Table 1 Cable lengths Model no. Cable length 4200-MTRX-1 1 meter 4200-MTRX-2 2 meters 4200-MTRX-3 3 meters Figure 1 Model 4200-MTRX-X cable Electrical specifications Electrical Impedance: 50 Frequency Range: 0 - 4GHz Working Voltage: Inner Shield to Outer Shield: 250 VDC Ctr. Conductor to Outer Shield: 250 VDC Ctr. Conductor to Inner Shield: <100V Insulation Resistance: 1

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Keithley 98932C(KPCMCIA_RS422_485S) - Keithley 6514RevA_DocSpec - Keithley Selector LowV-LowR - Keithley 2765 Thermistors - Keithley 052207 4ACS - Keithley 79480C(DASCard) - Keithley 3321RevB DocSpec -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Marantz PM14

script execution: 0.03 s